XBD-FS 4KC537 (150 mm × 125 mm) Fire Pump

EBARA XBD-FS 4KC537 pump is Back pull-out (BPO) structure, 150 × 125 caliber Fire Pump with 10/16 bar weight 136 kg and 25 bar weight 143 kg, It is a horizontal single-stage fire pump unit developed by our company according to market needs, which has high operating efficiency. The impeller and seal ring of EBARA XBD-FS 4KC537 Fire Pump Its performance and technical conditions meet the latest national standard GB6245-2008 “Fire Pump”. The product has been qualified by the Fire Products Conformity Assessment Center of the Ministry of Emergency Management and obtained the fire certification certificate..

In the detailed model name, XB indicates the model, 2 indicates the number of motor stages, HC indicates the impeller code, 5 indicates the frequency is 50 Hz, 37 indicates the motor power is 37 kW, 150 × 125 indicates the inlet and outlet diameters, and G indicates 10 bar type: -, 16 bar type: H, 25 bar type: G.

As part of EMAC, PumpMac provides abundant premium pump-driven power pack options, WPT PTO, Advance gearbox and pump head, as well as customized water pump set. We also have a set of NFPA20 standard engine power pack accessories including air intake shut-off valve, DC contactor, engine control panel, jacket water heater etc.

We provide full life cycle services for all customers, from design to power system supply, from installation to commissioning, from after-sales service training to spare parts supply, from trouble shooting to overhaul technical support.

Advantages of XBD-FS 4KC537 (150 mm × 125 mm) Fire Pump

  • Back pull-out (BPO) structure for easy maintenance.

  • Water outlet from the top center, pump housing supported by foot, stable structure.

  • Adopting Ebara’s patented hydraulic model, high operating efficiency.

  • Impeller and sealing ring are made of bronze.

  • Adopt bearings and mechanical seals of internationally renowned brands.

Technical Specifications

model: XBD-FS
flow: 7-240 L/S
Lift:
30.6-148 m
power:
4-3115 kW
Rotating speed:
 1480-2900 r/min
frequency: 50 Hz
Voltage: 380 V
Protection level: IP55
Gross weight: 110-2747 kg

coming soon

coming soon

coming soon

coming soon

Water Pump Model

Water Pump Diameter

Motor Poles

Synchronous Speed

Motor Power

Frequency

XBD-FS 4HC5.37 50mm × 40mm 4 1500min-1 0.4 kW 50 hz
XBD-FS 4HC5.75 50mm × 40mm 4 1500min-1 0.75 kW 50 hz
XBD-FS 4HC5.75 65mm × 50mm 4 1500min-1 0.75 kW 50 hz
XBD-FS 4JC51.5 65mm × 50mm 4 1500min-1 1.5 kW 50 hz
XBD-FS 4JC52.2 65mm × 50mm 4 1500min-1 2.2 kW 50 hz
XBD-FS 4GC5.75 80mm × 65mm 4 1500min-1 0.75 kW 50 hz
XBD-FS 4HC51.5 80mm × 65mm 4 1500min-1 1.5 kW 50 hz
XBD-FS 4JC52.2 80mm × 65mm 4 1500min-1 2.2 kW 50 hz
XBD-FS 4JC54.0 80mm × 65mm 4 1500min-1 4.0 kW 50 hz
XBD-FS 4KC57.5 80mm × 65mm 4 1500min-1 7.5 kW 50 hz
XBD-FS 4KC511 80mm × 65mm 4 1500min-1 11 kW 50 hz
XBD-FS 4GC51.5 100mm × 80mm 4 1500min-1 1.5 kW 50 hz
XBD-FS 4GC52.2 100mm × 80mm 4 1500min-1 2.2 kW 50 hz
XBD-FS 4HC52.2 100mm × 80mm 4 1500min-1 2.2 kW 50 hz
XBD-FS 4HC54.0 100mm × 80mm 4 1500min-1 4.0 kW 50 hz
XBD-FS 4JC55.5 100mm × 80mm 4 1500min-1 5.5 kW 50 hz
XBD-FS 4GC52.2 125mm × 100mm 4 1500min-1 2.2 kW 50 hz
XBD-FS 4GC54.0 125mm × 100mm 4 1500min-1 4.0 kW 50 hz
XBD-FS 4HC55.5 125mm × 100mm 4 1500min-1 5.5 kW 50 hz
XBD-FS 4JC55.5 125mm × 100mm 4 1500min-1 5.5 kW 50 hz
XBD-FS 4JC57.5 125mm × 100mm 4 1500min-1 7.5 kW 50 hz
XBD-FS 4JC511 125mm × 100mm 4 1500min-1 11 kW 50 hz
XBD-FS 4KC515 125mm × 100mm 4 1500min-1 15 kW 50 hz
XBD-FS 4KC518.5 125mm × 100mm 4 1500min-1 18.5 kW 50 hz
XBD-FS 4LC522 125mm × 100mm 4 1500min-1 22 kW 50 hz
XBD-FS 4LC530 125mm × 100mm 4 1500min-1 30 kW 50 hz
XBD-FS 4NC555 150mm × 100mm 4 1500min-1 55 kW 50 hz
XBD-FS 4NC575 150mm × 100mm 4 1500min-1 75 kW 50 hz
XBD-FS 4NC590 150mm × 100mm 4 1500min-1 90 kW 50 hz
XBD-FS 4HC57.5 150mm × 125mm 4 1500min-1 7.5 kW 50 hz
XBD-FS 4HC511 150mm × 125mm 4 1500min-1 11 kW 50 hz
XBD-FS 4HC515 150mm × 125mm 4 1500min-1 15 kW 50 hz
XBD-FS 4JC515 150mm × 125mm 4 1500min-1 15 kW 50 hz
XBD-FS 4JC518.5 150mm × 125mm 4 1500min-1 18.5 kW 50 hz
XBD-FS 4JC522 150mm × 125mm 4 1500min-1 22 kW 50 hz
XBD-FS 4KC530 150mm × 125mm 4 1500min-1 30 kW 50 hz
XBD-FS 4KC537 150mm × 125mm 4 1500min-1 37 kW 50 hz
XBD-FS 4LC545 150mm × 125mm 4 1500min-1 45 kW 50 hz
XBD-FS 4LC555 150mm × 125mm 4 1500min-1 55 kW 50 hz
XBD-FS 4LC575 150mm × 125mm 4 1500min-1 75 kW 50 hz
XBD-FS 4HC54.0 200mm × 150mm 4 1500min-1 4.0 kW 50 hz
XBD-FS 4HC55.5 200mm × 150mm 4 1500min-1 5.5 kW 50 hz
XBD-FS 4HC57.5 200mm × 150mm 4 1500min-1 7.5 kW 50 hz
XBD-FS 4HC511 200mm × 150mm 4 1500min-1 11 kW 50 hz
XBD-FS 4JC515 200mm × 150mm 4 1500min-1 15 kW 50 hz
XBD-FS 4JC518.5 200mm × 150mm 4 1500min-1 18.5 kW 50 hz
XBD-FS 4JC522 200mm × 150mm 4 1500min-1 22 kW 50 hz
XBD-FS 4JC530 200mm × 150mm 4 1500min-1 30 kW 50 hz
XBD-FS 4KC537 200mm × 150mm 4 1500min-1 37 kW 50 hz
XBD-FS 4KC545 200mm × 150mm 4 1500min-1 45 kW 50 hz
XBD-FS 4KC555 200mm × 150mm 4 1500min-1 55 kW 50 hz
XBD-FS 4LC575 200mm × 150mm 4 1500min-1 75 kW 50 hz
XBD-FS 4LC590 200mm × 150mm 4 1500min-1 90 kW 50 hz
XBD-FS 4NC5110 200mm × 150mm 4 1500min-1 110 kW 50 hz
XBD-FS 4NC5132 200mm × 150mm 4 1500min-1 132 kW 50 hz
XBD-FS 4NC5160 200mm × 150mm 4 1500min-1 160 kW 50 hz
XBD-FS 4KC530 250mm × 200mm 4 1500min-1 30 kW 50 hz
XBD-FS 4KC537 250mm × 200mm 4 1500min-1 37 kW 50 hz
XBD-FS 4KC545 250mm × 200mm 4 1500min-1 45 kW 50 hz
XBD-FS 4KC555 250mm × 200mm 4 1500min-1 55 kW 50 hz
XBD-FS 4KC575 250mm × 200mm 4 1500min-1 75 kW 50 hz
XBD-FS 4LC590 250mm × 200mm 4 1500min-1 90 kW 50 hz
XBD-FS 4LC5110 250mm × 200mm 4 1500min-1 110 kW 50 hz
XBD-FS 4LC5132 250mm × 200mm 4 1500min-1 132 kW 50 hz
XBD-FS 4LC5160 250mm × 200mm 4 1500min-1 160 kW 50 hz
XBD-FS 4NC5200 250mm × 200mm 4 1500min-1 200 kW 50 hz
XBD-FS 4NC5250 250mm × 200mm 4 1500min-1 250 kW 50 hz
XBD-FS 4NC5315 250mm × 200mm 4 1500min-1 315 kW 50 hz
——END——
EBARA XBD-FS 4KC537 Fire Pumps 2P/4P Head Diagram

Safety Instructions and Preventive Maintenance Guide

Requirements for use

Pumps play a significant role in a variety of industries and applications, ensuring the smooth movement of liquids and gases. However, in order to maintain top performance and safety, it is essential to adhere to routine maintenance procedures and safety recommendations. This guide aims at providing the detailed information about pump safety and preventive maintenance.

Safety Instructions

1. Read the Manual

 Before using EBara pumps, read and understand the handbook thoroughly. Make sure you understand the pump’s specifications, capabilities, and safety precautions.

2. Proper Installation

Ensure the pump is put appropriately according to the guidelines. Improper installation can cause operating inefficiencies and safety issues.

3. Ventilation

Operate pumps in well-ventilated areas to prevent the buildup of potentially harmful gases or vapors. If working in confined spaces, use proper ventilation equipment.

4. Emergency Shutdown Procedures

Familiarize yourself with emergency shutdown procedures in case of malfunction, leakage, or any other hazardous situation. Ensure all personnel know how to operate emergency shutdown mechanisms.

5. Regular Inspections

Conduct routine inspections of the pump and its components for signs of wear, damage, or leaks. Address any issues promptly to prevent accidents or system failures.

    6. Chemical Compatibility

    If handling hazardous chemicals, ensure the pump materials are compatible with the fluid being pumped or refer our chemical compatibility chart for more information. Incompatible materials can lead to corrosion, leaks, or chemical reactions.

    Preventive Maintenance

    1. Regular Lubrication

    Keep bearings, seals, and other moving parts properly lubricated. Insufficient lubrication can lead to premature wear and breakdowns.

    2. Inspect Seals and Gaskets

    Check seals and gaskets for wear, damage, or leaks regularly. Replace any worn or damaged seals to prevent fluid leakage and maintain pump efficiency.

     

    3. Check Motor Alignment

    Ensure the pump motor is properly aligned with the pump shaft to prevent excessive wear on bearings and seals. Misalignment can lead to premature failure and costly repairs.

    4. Replace Worn Parts

    Keep an inventory of spare parts and replace worn or damaged components as needed. Regularly check wear parts such as impellers, seals, and bearings for signs of deterioration.

    5. Schedule Maintenance

    Develop a preventive maintenance schedule based on manufacturer recommendations and operating conditions. Regular maintenance helps prevent unexpected breakdowns and extends the life of the pump.

    6. Document Maintenance Records

    Keep detailed records of all maintenance activities, including inspections, repairs, and replacements. This information helps track the pump’s performance over time and identify any recurring issues.

    By following these safety instructions and preventive maintenance practices, you can ensure the safe operation and longevity of your pumps while minimizing the risk of accidents or downtime. Remember, prioritizing safety and proactive maintenance is key to maximizing pump efficiency and reliability.

    Note: All Above Data are Just for Reference, All Data Might Change Without Notices or Updates, Please Contact Our Sales Team to Confirm All Details Via WhatsApp or Email.

    Global Activity

    Contact Us!

    Sales Team


    Construction-ConeMacWhatApp-Icon

    Pump-PumpMacWhatApp-Icon

    Mining-MinMacWhatApp-Icon

    Generator-SinoGenWhatApp-Icon

    EV System-EVMacWhatApp-Icon

    Parts-PartMacWhatApp-Icon


    Sales Manager-Mrs.Wendy FuWhatApp-Icon

    Sales Director-Mr.Jasper Lee WhatApp-Icon

    Shipping ServiceWhatApp-Icon

    Contact EMAC Now!

    premade-image-1

    Subscribe To Our Newsletter

    Subscribe to get the latest updates from ul-listed.com

    Welcome on board, we will keep you updated with latest news and business activities!

    Pin It on Pinterest